Summary
Copper calibrated access networks
Design of access networks has never been easier and faster. TeleCAD-GIS offers a powerful set of tools that does not inhibit the creativity of designers, on the other hand dramatically accelerates and automates time-consuming and repetitive processes. Possibility of errors arising due to the "human factor" is particularly reduced with such processes...
Topological hierarchy of structures - program allows immediate creation of hierarchical "tree" network, ie. display of telecommunication elements from situational plan of main distribution frame, through a complete network infrastructure of the detected cable line to the end user. Each structure in the tree can be found on the situation, read the actual load and attenuation, distance from the commutation...
Copper cables - complete sub-system for the automatic fitting lines according to a defined route, determination of the network (primary or distribution) and calculation of length (route, meandering, sling...). Rich, fillable catalog of copper cables is connected by the relations with the code list of materials from the specification.
Numbering of telecommunication elements - fully automated pairing and labeling of all network elements: extensions, cable splitter, termination boxes, cable reserves, user connections... Detection and numbering of cable lines can be serial or under rule of main branche. It is possible to define the type of the farthest element in the network, as well as numerous other processing. When numbering program offers automatic calculation of pairs' position in the main cable and the main hub for each of the elements of the situation.
Block diagram of distributor - fully adapted to the strict standards of geoinformation in a manner that the geometry of the network situation plan transforms into the orthogonal schematic representation. Automatically calculates the position of the user connection on disconnecting and shunting regleta of the terminal, positions of the spare pairs, and the position of subscribers on the main distribution hub.
Capacity optimization - automatic optimization of cable capacity of distributive (primary) and distributive network. Now it is enough only to lay cables for the route, and the application itself calculates the capacity that meets the requirements defined by the nodal elements. During optimization, if necessary, it can automatically optimize the conductor diameter (eg 0.4 to 0.6 mm), binding in installments is made if the user have not performed this operation, and optimization of the module and the type of connectors, depending on the capacity of the optimized cable is performed...
Numbering verification - specially adapted set of analytical tools - both for the designers, as well as the auditors of telecom operators: interactive verification of the validity of the numbering of telecommunication network facilities according to current standards. Possibility of showing the location and type of possible errors, and proposition of the correct numbering for each of the structures.
Block diagram of the primary - program by itself generates a block diagram of the primary network for a given cable route according to the situation plan. Scheme is in geospatial accordance with the situation, taking into account the structures of the cable canalization. Automatically calculates the live pairs in the primary cables, and the result is written to the block diagram.
Analysis of consistency - tools for capacitive and logical consistency checks of designed network structure: finding objects that are excluded from the network topology, warnings of insufficient capacity and the proposal of optimal capacity of primary and distribution cables. Also - proposing moving to the second diameter and warnings about illegal weakening of line, poor linking in installment, and numerous other analysis that help the designer to correct the prospective failures during network design.
Linking in installment - tools adapted to situations where in the node structure of telecommunication networks (for example, cable shaft) are built more installments, each of which may belong to different cable direction. Adapted to the logic design, with automatic selection of the appropriate type connectors from the catalog, depending on the characteristics of copper cables which are linking (capacity, diameter, etc.).
Linking in installment diagram - fully automated production of the schematic illustration of binding copper cables in installment, for all its installments in the selected cable direction. The program calculates or takes the entered label of installment. connector type, and determines the capacity and order of binding of input and output cables.
Specification designing - adjustable to material specifications of different telecom operators. Possibility of simultaneous processing of multiple cable routes, and graphic presentation of the reports. The generated reports can be exported into multiple formats: Microsoft Word or Excel, Adobe PDF, or XML format suitable for transport to other databases or object-modelers. When developing the specifications fully automated calculation of length and capacity is performed, or the quantity of all elements of the situation plan.
Table of terminals - automatic generating of the termination boxes table for a given cable route, where the program takes the existing data from the situation plan and places them into a table that can be immediately printed or exported in several different formats.
Card of terminals - automatic generating of the termination boxes and list of subscribers for a given structure or cable line, where the program takes the existing data or calculates the parameters of subscriber network: position of the pairs in the terminal, the main hub and phone numbers of subscribers, and the parameters of distribution network: the position of the pair on regleta and other subscriber information (number, name, address ...).
Inventory paper - automatically generating the table review suitable for direct printing based on the of data from a situation plan.
|